CP611LU,CP665 Standard type Oilless enclosed cylinders
Top seller among oilless enclosed type pneumatic cylinders.
With its high reliability and proven performance, this cylinder meets various applications in different fields.
■CP611LU Standard type Oilless enclosed cylinder(Bore size:φ40~φ100)
■CP665 Standard type Oilless enclosed cylinder(Bore size:φ125~φ500)
With its high reliability and proven performance, this cylinder meets various applications in different fields.
■CP611LU Standard type Oilless enclosed cylinder(Bore size:φ40~φ100)
■CP665 Standard type Oilless enclosed cylinder(Bore size:φ125~φ500)
Model code | Standard type | ||
---|---|---|---|
CP611LU | CP665 | ||
Operation type | Double acting | ||
Lubricant | none (Oilless) | ||
Bore size(mm) | φ40,50,63,80,100 | φ125,140,160,180,200,220,250 | φ300,350,400,450,450,500 |
Working pressure | 0.2~1.0MPa | ||
Piston speed | 50~500mm/s | 50~100mm/s | |
Thread tolerance | JIS(6H,6g) | ||
Cushion | Both ends (Air cushion) | ||
Proof pressure | 1.5MPa | ||
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
MP665 Oilless enclosed cylinders with solenoid valve
CP665 oilless enclosed cylinder with directly mounted 5-port solenoid valve.
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP665 Oilless enclosed cylinders with solenoid valve(Bore size:φ125~φ250)
This design enables easier piping and reduction in air consumption, thus lowering costs.
■MP665 Oilless enclosed cylinders with solenoid valve(Bore size:φ125~φ250)
Model code | Oilless enclosed cylinders with solenoid valve | ||||||
---|---|---|---|---|---|---|---|
MP665 | |||||||
Operation type | Double acting | ||||||
Lubricant | none (Oilless) | ||||||
Bore size(mm) | φ125,φ140 | φ160 | φ180 | φ200 | φ220 | φ250 | |
Working pressure | 0.2~1.0MPa | ||||||
Piston speed | 50~500mm/s | 50~400mm/s | 50~320mm/s | 50~260mm/s | 50~220mm/s | 50~170mm/s | |
Thread tolerance | JIS(6H,6g) | ||||||
Cushion | Both ends (Air cushion) | ||||||
Proof pressure | 1.5MPa | ||||||
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | ||||||
Solenoid valve | Model code | 4A3□ | |||||
Internal leakage | Below a specified value in JIS B8375 | ||||||
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | ||||||
Allowable voltage fluctuation | ±10% of applicable voltage | ||||||
Temperature rise | Max. 70℃ | ||||||
Insulation class | Class B | ||||||
Power consumption | AC:6VA DC:5.5W | ||||||
Response time | ≦ 0.05s |
●Refer to catalog for details.
SP665 Oilless enclosed cylinders with reed switch
Oilless enclosed cylinder based on CP665 with reed switch for detecting
stroke position.
This cylinder boasts high adaptability regardless of loads or operational environment.
■SP665 Oilless enclosed cylinders with reed switch(Bore size:φ125~φ200)
This cylinder boasts high adaptability regardless of loads or operational environment.
■SP665 Oilless enclosed cylinders with reed switch(Bore size:φ125~φ200)
Model code | Oilless enclosed cylinders with reed switch |
---|---|
SP665 | |
Operation type | Double acting |
Lubricant | none (Oilless) |
Bore size(mm) | φ125,140,160,180,200 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
Switch | Model code | SW-1 | SW-2 |
---|---|---|---|
Detecting method | Proximity of iron | ||
Rated voltage | AC/DC5~115V | AC100V~220V | |
Rated current | 2~60mA | 2~30mA | |
Power rating | 3W | 6VA | |
Lamp (Leakage current) |
LED light when switch is on ( - ) |
Neon lamp light up when switch is off (1mA or less) |
|
Isolation resistance | 20M Ω Min. | ||
Withstand voltage | 1,500V / min | ||
Ambient temp | -5~50℃ | ||
Protect construction | Equivalent to IP65 | ||
Internal circuit |
![]() |
![]() |
●Refer to catalog for details.
MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch
Oilless enclosed cylinders based on CP665 with 5-port solenoid valve and
reed switch.
Advantage of integration of each unit can be fully enjoyed.
■MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ125~φ200)
Advantage of integration of each unit can be fully enjoyed.
■MS665 Oilless enclosed cylinders with 5-port solenoid valve and reed switch(Bore size:φ125~φ200)
Model code | Oilless enclosed cylinders with 5-port solenoid valve and reed switch | ||||
---|---|---|---|---|---|
MS665 | |||||
Operation type | Double acting | ||||
Lubricant | none (Oilless) | ||||
Bore size(mm) | φ125,φ140 | φ160 | φ180 | φ200 | |
Working pressure | 0.2~1.0MPa | ||||
Piston speed | 50~500mm/s | 50~400mm/s | 50~320mm/s | 50~260mm/s | |
Thread tolerance | JIS(6H,6g) | ||||
Cushion | Both ends (Air cushion) | ||||
Proof pressure | 1.5MPa | ||||
Ambient temp | -5~50℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | ||||
Solenoid valve | Model code | 4A3□ | |||
Internal leakage | Below a specified value in JIS B8375 | ||||
Rated voltage | AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V | ||||
Allowable voltage fluctuation | ±10% of applicable voltage | ||||
Temperature rise | Max. 70℃ | ||||
Insulation class | Class B | ||||
Power consumption | AC:6VA DC:5.5W | ||||
Response time | ≦ 0.05s |
Switch | Model code | SW-1 | SW-2 |
---|---|---|---|
Detecting method | Proximity of iron | ||
Rated voltage | AC/DC5~115V | AC100V~220V | |
Rated current | 2~60mA | 2~30mA | |
Power rating | 3W | 6VA | |
Lamp (Leakage current) |
LED light when switch is on ( - ) |
Neon lamp light up when switch is off (1mA or less) |
|
Isolation resistance | 20M Ω Min. | ||
Withstand voltage | 1,500V / min | ||
Ambient temp | -5~50℃ | ||
Protect construction | Equivalent to IP65 | ||
Internal circuit |
![]() |
![]() |
●Refer to catalog for details.
CP611 General standard type (Heat-resistant)cylinders
Heavy duty type pneumatic cylinder with high rigidity and outstanding
durability that ensure secure operation even in serious environment.
■CP611 General standard type(Bore size:φ40~φ500)
■CP611H Heat-resistant type(Bore size:φ40~φ500)
■CP611S2 Bronze-welded piston type(Bore size:φ40~φ500)
■CP611S2H Bronze-welded piston type/heat-resistant type(Bore size:φ40~φ500)
■CP611 General standard type(Bore size:φ40~φ500)
■CP611H Heat-resistant type(Bore size:φ40~φ500)
■CP611S2 Bronze-welded piston type(Bore size:φ40~φ500)
■CP611S2H Bronze-welded piston type/heat-resistant type(Bore size:φ40~φ500)
Model code | General standard type | Heat-resistant type | Bronze-welded piston type | Bronze-welded piston type /heat-resistant type |
---|---|---|---|---|
CP611 | CP611H | CP611S2 | CP611S2H | |
Operation type | Double acting | |||
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) | |||
Bore size(mm) | φ40,50,63,80,100,125,140,160,180,200,220,250,300,350,400,450,450,500 | |||
Working pressure | 0.2~1.0MPa | |||
Piston speed | 50~500mm/s | |||
Thread tolerance | JIS(6H,6g) | |||
Cushion | Both ends (Air cushion) | |||
Proof pressure | 1.5MPa | |||
Ambient temp | -5~60℃ | 5~120℃ | -5~60℃ | 5~120℃ |
●The air must be dried the ambient temperature may drop below 5℃ to prevent
problems due to freezing.
●Refer to catalog for details.
●Refer to catalog for details.
CP691 Long-stroke cylinders(standard/heat-resistant)
Designed based on CP61 cylinders for long-stroke application,CP691 series
boast high rigidity with excellent reliability and proven performance.
■CP691 Long-stroke cylinders(standard)(Bore size:φ40~φ250)
■CP691H Long-stroke cylinders(heat-resistant)(Bore size:φ40~φ250)
■CP691 Long-stroke cylinders(standard)(Bore size:φ40~φ250)
■CP691H Long-stroke cylinders(heat-resistant)(Bore size:φ40~φ250)
Model code | Long-stroke cylinders(standard) | Long-stroke cylinders(heat-resistant) |
---|---|---|
CP691 | CP691H | |
Operation type | Double acting | |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) | |
Bore size(mm) | φ40,50,63,80,100,125,140,160,180,200,220,250 | |
Working pressure | 0.2~1.0MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.5MPa | |
Ambient temp | -5~60℃ | 5~120℃ |
●The air must be dried the ambient temperature may drop below 5℃ to prevent
problems due to freezing.
●Refer to catalog for details.
●Refer to catalog for details.
CP61SU Corrosion-resistant cylinders
Corrosion-resistant pneumatic cylinder based on CP611 with stainless steel
external materials.
■CP61SU Corrosion-resistant pneumatic cylinder(Bore size:φ40~φ250)
■CP61SU Corrosion-resistant pneumatic cylinder(Bore size:φ40~φ250)
Model code | Corrosion-resistant surface type |
---|---|
CP61SU | |
Operation type | Double acting |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) |
Bore size(mm) | φ40,50,63,80,100,125,140,160,180,200,220,250 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
CP611DR Double rod type cylinders
Double rod cylinder designed based on CP611 pneumatic cylinder.
■CP611DR Double rod type(Bore size:φ40~φ100)
■CP611DR Double rod type(Bore size:φ40~φ100)
Model code | Double rod type |
---|---|
CP611DR | |
Operation type | Double acting |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) |
Bore size(mm) | φ40,50,63,80,100 |
Working pressure | 0.2~1.0MPa |
Piston speed | 50~500mm/s |
Thread tolerance | JIS(6H,6g) |
Cushion | Both ends (Air cushion) |
Proof pressure | 1.5MPa |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
CP611AD CP611AR Stroke adjustable type cylinders
This CP611-based general purpose pneumatic cylinder with adjustable stroke
is available in 2 types: AD type adjusts stroke at rod "IN" and AR type
at rod "OUT".
■CP611AD Rod-in stroke adjustable type(Bore size:φ40~φ100)
■CP611AR Rod-out stroke adjustable type(Bore size:φ40~φ100)
■CP611AD Rod-in stroke adjustable type(Bore size:φ40~φ100)
■CP611AR Rod-out stroke adjustable type(Bore size:φ40~φ100)
Model code | Rod-in stroke adjustable type | Rod-out stroke adjustable type |
---|---|---|
CP611AD | CP611AR | |
Operation type | Double acting | |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) | |
Bore size(mm) | φ40,50,63,80,100 | |
Working pressure | 0.2~1.0MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.5MPa | |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.
CP611M CP611MR MILL type cylinders
Heavy duty pneumatic cylinder based on CP611S2 with flangewelded cylinder
tube.
■CP611M MILL type with screwed rod(Bore size:φ40~φ500)
■CP611MR MILL type with integrated rod eye(Bore size:φ40~φ500)
■CP611M MILL type with screwed rod(Bore size:φ40~φ500)
■CP611MR MILL type with integrated rod eye(Bore size:φ40~φ500)
Model code | MILL type with screwed rod | MILL type with integrated rod eye |
---|---|---|
CP611M | CP611MR | |
Operation type | Double acting | |
Lubricant | Lubricant(Use JIS K 2213,ISO VG32 or VG46 type turbine oil for lubrication using a lubricator.) | |
Bore size(mm) | φ40,50,63,80,100,125,140,160,180,200,220,250,300,350,400,450,450,500 | |
Working pressure | 0.2~1.0MPa | |
Piston speed | 50~500mm/s | |
Thread tolerance | JIS(6H,6g) | |
Cushion | Both ends (Air cushion) | |
Proof pressure | 1.5MPa | |
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) |
●Refer to catalog for details.