■Space-saving type to meet factory requirements
Cable cylinders are designed to reduce installation space and require only half the space needed for rod cylinders.
■Excellent versatility allowing functional design
Stroke length can be set up to 18 m using tube coupler.
■Factory automation-oriented multiple functions
Cable coated with special nylon is highly airtight and strong enough to resolve problems of friction and bending due to heavy rod.
Cable cylinders are designed to reduce installation space and require only half the space needed for rod cylinders.
■Excellent versatility allowing functional design
Stroke length can be set up to 18 m using tube coupler.
■Factory automation-oriented multiple functions
Cable coated with special nylon is highly airtight and strong enough to resolve problems of friction and bending due to heavy rod.
CC series Double acting (standard) CC:Pneumatic CCV:Hydraulic
■Bore size:12.7mm(1/2")~101.6mm(4")
■Space needed for installation is only half that of rod cylinders.
Problem of bending due to heavy rod can be solved.
■Space needed for installation is only half that of rod cylinders.
Problem of bending due to heavy rod can be solved.
Model code | Pneumatic | CC05 | CC07 | CC10 | CC15 | CC20 | CC25 | CC30 | CC40 | CC52 |
---|---|---|---|---|---|---|---|---|---|---|
Hydraulic | - | CCV07 | CCV10 | CCV15 | CCV20 | CCV25 | CCV30 | CCV40 | CCV52 | |
Bore size | (mm) | 12.7 | 19.1 | 25.4 | 38.1 | 50.8 | 63.5 | 76.2 | 101.6 | 50.8 |
(inch) | 1/2" | 3/4" | 1" | 1 1/2" | 2" | 2 1/2" | 3" | 4" | 2" | |
Max.Working pressure | 0.7MPa | 1.4MPa | 3.5MPa | |||||||
Max. permissible piston speed |
Pneumatic | 500mm/s | 1000m/s | 500m/s | 1000mm/s | |||||
Hydraulic | 200mm/s | 200m/s | 1000m/s | 500m/s | ||||||
Tube materials | Steel | - | - | ● | ● | ● | ● | ● | ● | ● |
Aluminum | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Tube surface | Steel | Lacquer paint | ||||||||
Aluminum | Alumite finish | |||||||||
Cushion | None | Both ends(fixed orifice) | Both ends(variable type) | |||||||
Ambient temp | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | |||||||||
Option | Automatic tensioner | - | ● | ● | ● | ● | ● | ● | ● | ● |
Reed switches | ● | ● | ● | ● | ● | ● | ● | ● | ● |
●Refer to catalog for details.
SA series Single acting SA:Pneumatic SAV:Hydraulic
■Bore size:19.1mm(3/4")~50.8mm(2")
■Pneumatic cylinder that returns by gravity. SA series are suitable for load lifting applications. The cylinder supplies pressure only at lifting up a load.
■Installation of the cylinder can be horizontal, perpendicular, or slope.
■Pneumatic cylinder that returns by gravity. SA series are suitable for load lifting applications. The cylinder supplies pressure only at lifting up a load.
■Installation of the cylinder can be horizontal, perpendicular, or slope.
Model code | Pneumatic | SA07 | SA10 | SA15 | SA20 | SA25 | SA30 | SA40 | SA52 |
---|---|---|---|---|---|---|---|---|---|
Hydraulic | SAV07 | SAV10 | SAV15 | SAV20 | SAV25 | SAV30 | SAV40 | SAV52 | |
Bore size | (mm) | 19.1 | 25.4 | 38.1 | 50.8 | 63.5 | 76.2 | 101.6 | 50.8 |
(inch) | 3/4" | 1" | 1 1/2" | 2" | 2 1/2" | 3" | 4" | 2" | |
Max.Working pressure | 0.7MPa | 1.4MPa | 3.5MPa | ||||||
Tube materials | Steel | - | ● | ● | ● | ● | ● | ● | ● |
Aluminum | ● | ● | ● | ● | ● | ● | ● | ● | |
Tube surface | Steel | Lacquer paint | |||||||
Aluminum | Alumite finish | ||||||||
Cushion | Both ends(fixed orifice) | Both ends(variable type) | |||||||
Ambient temp. | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | ||||||||
Option | Reed switches | ● | ● | ● | ● | ● | ● | ● | ● |
●Refer to catalog for details.
DP series With double purchase kit DP:Pneumatic DPV:Hydraulic
■Bore size:38.1mm(1 1/2")~50.8mm(2")
■Load can be traveled double the length of cylinder stroke.
■Ensures further space-saving compared to standard type.
■Load can be traveled double the length of cylinder stroke.
■Ensures further space-saving compared to standard type.
Model code | Pneumatic | DP15 | DP20 | DP25 | DP30 | DP40 | DP52 |
---|---|---|---|---|---|---|---|
Hydraulic | DPV15 | DPV20 | DPV25 | DPV30 | DPV40 | DPV52 | |
Bore size | (mm) | 38.1 | 50.8 | 63.5 | 76.2 | 101.6 | 50.8 |
(inch) | 1 1/2" | 2" | 2 1/2" | 3" | 4" | 2" | |
Max.Working pressure | 0.7MPa | 1.4MPa | 3.5MPa | ||||
Tube materials | Steel | ● | ● | ● | ● | ● | ● |
Aluminum | ● | ● | ● | ● | ● | ● | |
Tube surface | Steel | Lacquer paint | |||||
Aluminum | Alumite finish | ||||||
Cushion | Both ends(variable type) | ||||||
Ambient temp. | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | ||||||
Option | Automatic tensioner | ● | ● | ● | ● | ● | ● |
Reed switches | ● | ● | ● | ● | ● | ● |
●Refer to catalog for details.
TC series With tracking rail TC:Pneumatic TCV:Hydraulic
■Bore size:12.7mm(1/2")~38.1mm(1 1/2")
■TC series cable cylinders with tracking rail have linear bearing at load mounting block.It runs on the quenched ground shaft.
Without need for guide to support loads, it is easy to install.
■TC series cable cylinders with tracking rail have linear bearing at load mounting block.It runs on the quenched ground shaft.
Without need for guide to support loads, it is easy to install.
Model code | Pneumatic | TC05 | TC07 | TC10 | TC15 |
---|---|---|---|---|---|
Hydraulic | - | TCV07 | TCV10 | TCV15 | |
Bore size | (mm) | 12.7 | 19.1 | 25.4 | 38.1 |
(inch) | 1/2" | 3/4" | 1" | 1 1/2" | |
Max.Working pressure | 0.7MPa | ||||
Tube materials | Steel | - | - | ● | ● |
Aluminum | ● | ● | ● | ● | |
Tube surface | Steel | Lacquer paint | |||
Aluminum | Alumite finish | ||||
Cushion | None | Both ends(fixed orifice) | Both ends(variable type) | ||
Ambient temp. | -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.) | ||||
Option | Automatic tensioner | - | ● | ● | ● |
Reed switches | ● | ● | ● | ● |
●Refer to catalog for details.
Option Automatic tesioner
Automatic tensioner always gives certain degree of tension to the cable.
As good relationship between cable and ground seal are maintained, longer seal life is guaranteed.
No bending due to stretched cable occurs, minimizing wearing of cable.
As good relationship between cable and ground seal are maintained, longer seal life is guaranteed.
No bending due to stretched cable occurs, minimizing wearing of cable.
●Refer to catalog for details.
Option Reed switches
As piston incorporating magnet comes closer to reed switch, contact is
closed and switch turns ON.
Suitable for operation check, detection, and interlock as a controller of sequencer or computer.
Can be mounted on a cylinder with automatic tensioner and tracking rail.
Suitable for operation check, detection, and interlock as a controller of sequencer or computer.
Can be mounted on a cylinder with automatic tensioner and tracking rail.
Model code | RT | BT | CT形(TRIAC) |
---|---|---|---|
Circuit | Single pole,Single circuit | Single pole,Double circuit | Single pole,Single circuit |
Applicable voltage | MAX DC200V | MAX DC175V | AC100・110V(50/60Hz) |
Max. Contact capacity | MAX 10VA | MAX 3VA | - |
Max. Operating current | 0.5A(at 40℃) | 0.25A(at 40℃) | 1.0A(at 30℃) |
Response time | 1ms or less | 1ms or less | 1ms or less |
Ambient temp | -40~70℃ | -40~60℃ | |
Leakage current | - | - | 1mA or less |
Indicator | LED | - | - |
Wiring diagrams |
![]() |
![]() |
![]() |
Leadwire length | 5m | 5m | 5m |
●Refer to catalog for details.